At Passcerty.com, we pride ourselves on the comprehensive nature of our E20-807 exam dumps, designed meticulously to encompass all key topics and nuances you might encounter during the real examination. Regular updates are a cornerstone of our service, ensuring that our dedicated users always have their hands on the most recent and relevant Q&A dumps. Behind every meticulously curated question and answer lies the hard work of our seasoned team of experts, who bring years of experience and knowledge into crafting these premium materials. And while we are invested in offering top-notch content, we also believe in empowering our community. As a token of our commitment to your success, we're delighted to offer a substantial portion of our resources for free practice. We invite you to make the most of the following content, and wish you every success in your endeavors.


Download Free EMC E20-807 Demo

Experience Passcerty.com exam material in PDF version.
Simply submit your e-mail address below to get started with our PDF real exam demo of your EMC E20-807 exam.

Instant download
Latest update demo according to real exam

*Email Address

* Our demo shows only a few questions from your selected exam for evaluating purposes

Free EMC E20-807 Dumps

Practice These Free Questions and Answers to Pass the DECE-Implementation Engineer Exam

Questions 1

A VMAX3 array needs additional capacity added. The array is providing acceptable performance and the administrator wants to ensure performance is maintained as new drives are added.

A VMAX3 array needs additional capacity added to maintain performance?

A. Add storage to all tiers maintaining the existing ratio

B. Add storage to a new internal SRP

C. Add storage to the most over utilized tier

D. Add storage to a new external SRP

Show Answer
Questions 2

SRDF/Metro has been deployed in a non-Witness configuration. Each data center has one VMAX3 array. What is the SRDF pair state under normal operating conditions?

A. Consistent

B. Synchronized

C. ActiveActive

D. ActiveBias

Show Answer
Questions 3

An existing single engine VMAX3 with two FC ports configured for remote replication will be adding FAST.X to a CloudArray. Currently the array is configured with 32 FC ports which are all in use.

Which steps are required to support a minimum connectivity to the CloudArray?

A. Identify a port on each director to be used for the DX emulation Remove replication from any devices on the selected ports Delete any volumes presented to those ports

B. Identify two ports on each director to be used for the DX emulation. Stop all remote replication Delete any volumes presented to those ports.

C. Identify two ports on a single director to be used for the DX emulation Remove any masking entries related to the director ports

D. Identify two ports on each director to be used for the DX emulation Remove any masking entries to the director ports.

Show Answer
Questions 4

On a VMAX3 array, for which type of workload does FlashBoost help in optimizing performance?

A. Sequential Reads

B. Sequential Writes

C. Random Writes

D. Random Reads

Show Answer
Questions 5

What is a requirement for Non-Disruptive Migration (NDM) to a VMAX All Flash or VMAX3 array?

A. Application host connected through FC to both arrays

B. Application host connected through FC to only the source array

C. Individual NDM licenses on both arrays

D. eManagement running on both arrays

Show Answer