Exam Code: DES-4121
Exam Name: PowerEdge Specialist Exam for Implementation Engineer
Updated: Apr 14, 2024
Q&As: 60
At Passcerty.com, we pride ourselves on the comprehensive nature of our DES-4121 exam dumps, designed meticulously to encompass all key topics and nuances you might encounter during the real examination. Regular updates are a cornerstone of our service, ensuring that our dedicated users always have their hands on the most recent and relevant Q&A dumps. Behind every meticulously curated question and answer lies the hard work of our seasoned team of experts, who bring years of experience and knowledge into crafting these premium materials. And while we are invested in offering top-notch content, we also believe in empowering our community. As a token of our commitment to your success, we're delighted to offer a substantial portion of our resources for free practice. We invite you to make the most of the following content, and wish you every success in your endeavors.
Experience Passcerty.com exam material in PDF version.
Simply submit your e-mail address below to get started with our PDF real exam demo of your EMC DES-4121 exam.
Instant download
Latest update demo according to real exam
A technician receives a repurposed PowerEdge server. After racking and cabling the server, the technician attempts to log into the iDRAC but cannot do so. The default account has been disabled.
What method can be used to enable the default login account?
A. Run the racadm recreset command from the host OS.
B. Run the racadm recresetcfg command from the host OS.
C. SSH into the iDRAC and run the racadm racresetcfg command.
D. SSH into the iDRAC and run the racadm racreset command.
A technician is ready to deploy a server. If a critical part such as the system board fails, they must be able to replace the system board, reconfigure components, and update the firmware revisions in the fastest possible time.
How should the technician meet this requirement?
A. Back up the profile using the System Profile Settings
B. Use the iDRAC Rollback feature to restore the firmware revisions
C. Use the iDRAC GUI to back up the Server Profile
D. Back up component configurations using iSM
A technician needs to troubleshoot a server. The OS had been operational, but an untrained person accessed the System Setup utility on the server and now the OS fails to load. The technician reboots the server, selects F2, accesses the System Setup utility, and selects System BIOS.
What two items should the technician verify in the System BIOS settings before reloading the OS?
A. Boot Settings > Boot Option Settings > Boot Sequence Integrated Devices > OS Watchdog Timer
B. Boot Settings > Boot Mode Boot Settings > Boot Option Settings > Boot Sequence
C. Boot Settings > Boot Mode Integrated Devices > OS Watchdog Timer
D. Boot Settings > Boot Mode Device Settings > Boot Sequence
A technician is remotely installing ESXi 6.0 on a PowerEdge R640 in BIOS boot mode. The system has dual internal SD cards. After the OS is installed, the system reboots and shows an error screen with the following message: "No boot device found".
What should the technician do to resolve this issue?
A. Enable vFlash in iDRAC web GUI
B. Set the boot made from BIOS to UEFI
C. Reseat the SD cards and try to boot to them again
D. Change the Hard Disk Drive Sequence
A server has two power supply units (PSUs) in a redundant configuration. One PSU fails. A technician replaces the failed PSU, but the server does not return to redundant power mode.
What is the cause of this issue?
A. Power redundant option is disabled in the System Setup Utility.
B. Server has not been power cycled to bring the new PSU online
C. Both PSUs were not replaced at the same time
D. New PSU has a different wattage than the existing PSU
Viewing Page 1 of 3 pages. Download PDF or Software version with 60 questions